134H8853 DANFOSS DRIVES VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 480 VAC, Safe Stop, IP21 / Type 1, RFI c.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

134H8853 DANFOSS DRIVES VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 480 VAC, Safe Stop, IP21 / Type 1, RFI c..

134H8853

134H8853

DANFOSS DRIVES

Available

Ship on today

VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI class A1 (C2), No A Option, No B Option, Coated PCB, Mains Disconnect + Fuse FC-102N160T4E21H4TGC3XXSXXXXAXBXCXXXXDX

More details


Variable Adjustable Frequency Speed Drives Inverters Vfd Vvvf Voltage

VLT FC102 HVAC - DANFOSS DRIVES

* Brand new produt in its original packing covered by the warranties and certifications provided by DANFOSS DRIVES

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



CHARACTERISTICVALUE
PRODUCT VIEW (SWITCH)Global (Standard)
PRODUCT GROUP(FC-) VLT® HVAC Drive
SERIES(102) HVAC Advanced version
POWER RATING(N160) 160 KW / 250 HP
PHASE(T) Three phase
MAINS VOLTAGE(4) 380 - 480 VAC
ENCLOSURE(E21) IP21 / Type 1
RFI FILTER(H4) RFI class A1 (C2)
BRAKE - SAFE STOP(T) Safe Stop
LCP(G) Graphical Loc. Cont. Panel
COATING PCB(C) Coated PCB
MAINS OPTION(3) Mains Disconnect + Fuse
ADAPTATION A(X) Standard Cable Entries
ADAPTATION B(X) No adaptation
SOFTWARE RELEASE(SXXX) Latest release std. SW.
SOFTWARE LANGUAGE PACK(X) Standard Language Pack
A OPTION(AX) No A Option
B OPTION(BX) No B Option
C0 OPTION MCO(CX) No C0 option
C1 OPTION(X) No C1 option
C OPTION SOFTWARE(XX) No software option
D OPTION(DX) No D option
FRAME SIZED5H
PRODUCT CATALOGNO VIEW
TYPECODEFC-102N160T4E21H4TGC
TYPECODE PART 23XXSXXXXAXBXCXXXXDX
ORIGINAL PRODUCT MATRIX(STD) Standard Drive
VENDORCannot Determine Vendor
VENDOR REGIONCannot Determine Region
CALCULATED GROSS WEIGHT166,300
CALCULATED NET WEIGHT166,000
MATERIAL GROSS WEIGHT146,000
MATERIAL NET WEIGHT106,000

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOEnglish2 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf1-VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOSS DRIVEEnglish5 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf2-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOEnglish3 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf2-VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOSS DRIVEEnglish4 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf3-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOEnglish4 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf3-VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOSS DRIVEEnglish8 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf4-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOEnglish878 Kbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf4-VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOSS DRIVEEnglish8 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf5-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOEnglish974 Kbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO
pdf5-VLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFOSS DRIVEEnglish7 Mbytespdf1-mostradoVLT® HVAC Drive FC 102 160 KW / 250 HP, 380 - 480 VAC, Safe Stop, IP21 / Type 1, RFI cla - DANFO

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or