Selected parameters SYSTEM System SENSING FUNCTION Filling or Emptying CONNECTION Terminals OUTPUT Relay SPDT MATERIAL NORYL Others HOUSING 35,5 x 81 x 60 mm SENSING FUNCTION 5 koHm to 150 koHm MATERIAL NORYL

More details


Level Sensors Detectors Measurement

Sensors

Conductive Level Sensors

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$48.50
5+$44.96
9+$44.04
13+$43.54
18+$43.20
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Conductive Sensors
2-point level controller
Type CL with potentiometer
• Conductive level controller
• Sensitivity adjustment from 5 kΩ to 150 kΩ
• For filling or emptying applications
• Low-voltage AC electrodes
• Easy installation with 11 pin circular plug
• Rated operational voltage:
24 VDC, 24 VAC, 115 VAC or 230 VAC
• Output 1 x 8A/250 VAC SPDT relay
• LED indication for: Output ON and Power ON
Product Description
Ordering Key
CLP2EB1B230
µ-Processor based level controller for liquids with a wide sensitivity range (like sewage water, chemicals, salt water etc.).
Max./min. control of charging/ discharging. The sensitivity is adjustable by means of the potentiometer.
1 x 8A SPDT relay output.
Conductive level Plug mounting No of inputs
Charge/discharge
Basic with potentiometer
1 relay output Relay SPDT Power supply
Type Selection
Mounting Relay Ordering no. Ordering no. Ordering no. Ordering no.
Supply: 24 VDC Supply: 24 VAC Supply: 115 VAC Supply: 230 VAC
11-p circular plug SPDT CLP2EB1B724 CLP2EB1B024 CLP2EB1B115 CLP2EB1B230
Specifications
Rated operational voltage (UB)
Pin 2 & 10 230 195 to 265 VAC, 45 to 65 Hz
115 98 to 132 VAC, 45 to 65 Hz
024 20.4 to 27.6 VAC, 45 to 65 Hz
Supply class 2 724 20.4 to 27.6 VDC Rated insulation voltage <2.0 kVAC (rms) Rated impulse withstand
voltage 4 kV (1.2/50 µs) (line/neutral)
Rated operational power
AC supply 5 VA DC supply 1 W
Delay on operate (tV) < 2 s
Outputs
Rated insulation voltage 250 VAC (rms) (cont./elec.)
Relay Rating (AgCdO) µ (micro gap)
Resistive loads AC1 8 A / 250 VAC (2500 VA) DC1 1 A / 250 VDC (250 W)
or 10 A / 25 VDC (250 W) Small induc. Loads AC15 0,4 A / 250 VAC
DC13 0,4 A / 30 VDC Mechanical life (typical) ≥ 30 x 106 operations
@ 18’000 imp/h
Electrical life (typical) AC1 > 250’000 operations
Level probe supply Max. 5 VAC
Level probe current Max. 2 mA
Sensitivity 5 kΩ to 150 kΩ, CF* = 2.2 nF
Dielectric voltage >2.0 KVAC (rms) (contacts / electronics)
Rated impulse withstand volt. 4 kV (1.2/50 µS) (contacts /
electronics) (IEC 664)
Operating frequency (f)
Relay output 1 Hz
Response time
OFF-ON (ton) 1 s
ON-OFF (toff) 1 s
Environment
Overvoltage category III (IEC 60664)
Degree of protection IP 20 (IEC 60529, 60947-1) Pollution degree 2 (IEC 60664/60664A,
60947-1)
Temperature
Operating -20º to +50ºC (-4º to + 122ºF) Storage -40º to +85ºC (-40º to +185ºF)
Housing material NORYL PPO, light grey
Weight
AC supply 180 g
DC supply 70 g
Approvals cURus UL508, CSA C22.2
CSA CSA C22.2
CE marking Yes
*CF = maximum Cable Capacitance
Specifications are subject to change without notice (26.08.2014) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters SYSTEM System SENSING FUNCTION Filling or Emptying CONNECTION Te - CARLO GAVAEnglish232 Kbytespdf1-mostradoSelected parameters SYSTEM System SENSING FUNCTION Filling or Emptying CONNECTION Te - CARLO GAVA
pdf1-Selected parameters SYSTEM System SENSING FUNCTION Filling or Emptying CONNECTION Te - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters SYSTEM System SENSING FUNCTION Filling or Emptying CONNECTION Te - CARLO GAVA
pdf2-mostradoSelected parameters SYSTEM System SENSING FUNCTION Filling or Emptying CONNECTION Te - CARLO GAVAEnglish200 Kbytespdf1-mostradoSelected parameters SYSTEM System SENSING FUNCTION Filling or Emptying CONNECTION Te - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or