RGC3P60V30EAP CARLO GAVAZZI Selected parameters SYSTEM DIN-rail Mount CURRENT RATING CATEGORY 26 50 AAC RATE.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

RGC3P60V30EAP CARLO GAVAZZI Selected parameters SYSTEM DIN-rail Mount CURRENT RATING CATEGORY 26 50 AAC RATE..

RGC3P60V30EAP

RGC3P60V30EAP

CARLO GAVAZZI

Available

Ship on today

Selected parameters SYSTEM DIN-rail Mount CURRENT RATING CATEGORY 26 - 50 AAC RATED VOLTAGE 600 VAC OUTPUT SWITCHING MODE Phase Angle Control NUMBER OF POLES 3 CONTROL DC - ANALOGUE POWER CONNECTION Box Clamp MODEL Proportional Controllers Others CURRENT RATING 30AAC @ 40°C (104°F) integrated heatsink CONTROL INPUT 0...10VDC, 0...5VDC, 1...5VDC, potentiometer PRODUCT WIDTH 70mm

More details


Solid State Relays Ssr

Switches

Industrials Relays, Solid State Relays and sockets

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$245.27
2+$239.56
3+$236.74
4+$236.38
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Solid State Relays
3-Phase with Integrated Heatsink
Proportional Switching Controllers
Types RGC2P, RGC3P
• 2-pole and 3-pole analog switching solid state contactors
• Rated operational voltage: up to 660VAC
• Rated operational current: up to 75AAC
• Control inputs: 0-20mA, 4-20mA, 12-20mA, 0-5V, 1-5V, 0-10V
• Local setting through external potentiometer
• Switching modes: phase angle or distributed full cycles (1, 4 or 16 full cycles)
• Soft start feature with selectable ramp time up to 5 seconds
• Integrated varistor protection on output
• Monitoring for SSR and load malfunction
• EMR output for alarm indication
• 100kA short circuit current rating according to UL508
• DIN or panel mount
Product Description Ordering Key
RGC 3 P 60 V 65 C1 D F M
This series gives the possibility to control output power of 3- phase loads with an analog control input. The RGC2P is a 2- phase switching product whilst the RGC3P switches all 3 phases.
Input types cover a wide range of current and voltage ranges. Local setting by an external potentiometer is also possible. Switching modes cover phase angle control, distributed full
cycle control and soft start for limiting inrush current of loads having a high temperature coefficient, such as short wave infrared heaters.
Detection of mains loss, load loss, SSR short circuit and over- temperature is integrated in some models. Alarm condition is signalled through an EMR output and is visually indicated by the alarm LED. Additional LEDs indicate input and load status.
Solid state relay
Number of switched poles
Type of switching
Rated operational voltage
Control input
Rated operational current
Switching mode External supply Integrated fan Monitoring features
Specifications are at a surrounding temperature of 25°C unless otherwise specified.
Ordering Key (Refer to page 4 for valid part numbers)
SSR with heatsink
Type of switching
Rated voltage (Ue), Blocking voltage
Control input1
Rated current/ pole
@40°C2
Switching mode
External supply (Us)
Features
RGC2:
2-pole switching +
1-pole direct
P: Proportional 60:
180 - 660VAC,
1200Vp
AA:
4-20mADC
I:
0-20mADC
4-20mADC
12-20mADC
V:
0-5VDC
1-5VDC
0-10VDC
15: 15AAC
25: 25AAC
40: 40AAC
75: 75AAC
C1: 1 FC ON,
1FC OFF @
50% input
C4: 4 FC ON,
4FC OFF @
50% input
D: 24VAC/DC
A: 90 - 250VAC
F: Integrated fan
M: Monitoring for Mains loss, Load loss, SSR short circuit, open circuit and OTP with EMR alarm output
RGC3:
3-pole switching
FC = Full Cycle
P: Proportional 60:
180 - 660VAC,
1200Vp
AA:
4-20mADC
I:
0-20mADC
4-20mADC
12-20mADC
V:
0-5VDC
1-5VDC
0-10VDC
20: 20AAC
30: 30AAC
65: 65AAC
E: Phase Angle
C1: 1 FC ON,
1FC OFF @
50% input
C4: 4 FC ON,
4FC OFF @
50% input
C16: 16 FC ON,
16FC OFF @
50% input
S: Soft Start
D: 24VAC/DC
A: 90 - 250VAC
P: Integrated over temperature protection (OTP), mains loss with EMR alarm output
F: Integrated fan
M: Monitoring for Mains loss, Load loss, SSR short circuit, open circuit and
OTP = Over Temperature Protection
EMR = Electromechanical Relay
1. Input types I and V require an external supply Us
2. Refer to Derating Curves
S16: Soft Start +
mode C16
OTP with EMR
alarm output
Specifications are subject to change without notice (26.05.2015) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters SYSTEM DIN-rail Mount CURRENT RATING CATEGORY 26 - 50 AAC RATED - CARLO GAVAEnglish5 Mbytespdf1-mostradoSelected parameters SYSTEM DIN-rail Mount CURRENT RATING CATEGORY 26 - 50 AAC RATED - CARLO GAVA
pdf1-Selected parameters SYSTEM DIN-rail Mount CURRENT RATING CATEGORY 26 - 50 AAC RATED - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters SYSTEM DIN-rail Mount CURRENT RATING CATEGORY 26 - 50 AAC RATED - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or