Selected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3-phase AC voltage monitoring Others SIZE 36 mm POWER SUPPLY RANGE 380÷415 VAC MONITORING FUNCTION Under and over voltage, phase sequence/loss, asymmetry, tolerance MOUTING Plug-in INPUT RANGE 380÷415 VAC OTHERS VLN monitoring

More details


Energy Meters Control Analizers

Controls

Monitoring Relays and Measurement Current Transformers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$212.28
2+$207.15
3+$204.61
4+$203.47
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Monitoring Relays
True RMS 3-Phase, 3-Phase+N, Multifunction
Types DPC71, PPC71
DPC71 PPC71
• TRMS 3-phase over and under voltage,
phase sequence, phase loss, asymmetry and tolerance monitoring relay
• Detect when all 3 phases are present and have the correct sequence
• Detect if all the 3-phase-phase or phase-neutral voltages are within the set limits
• Detect if asymmetry and tolerance are within the set value
• Separately adjustable setpoints
• Separately adjustable delay functions (0.1 to 30 s)
• Output: 2 x 5 A relay SPDT NE
• For mounting on DIN-rail in accordance with
DIN/EN 50 022 (DPC71) or plug-in module (PPC71)
• 35.5 mm Euronorm housing (DPC71) or 35.5 mm plug- in module (PPC71)
• LED indication for relays, alarm and power supply ON
Product Description Ordering key
DPC 71 D M48
3-phase or 3-phase+neutral line voltage monitoring relay for phase sequence, phase loss, asymmetry, tolerance, over and under voltage (sep- arately adjustable set points)
Type Selection
with built-in time delay func- tion.
Supply ranges from 208 to
480 VAC covered by two multivoltage relays.
Housing Function Type
Item number
Output
Power Supply
Supply: Supply: Supply: Mounting Output Frequency 208 to 240 VAC 380 to 415 VAC 380 to 480 VAC
DIN-rail 2 x SPDT 50 - 60 Hz DPC 71 D M23 DPC 71 D M48
Plug-in 2 x SPDT 50 - 60 Hz PPC 71 D M23 PPC 71 D M48
Input Specifications
Input
L1, L2, L3, N DPC71: Terminals L1, L2, L3, N PPC71: Terminals 5, 6, 7, 11
Measure their own supply
Note: Connect the neutral only if it is intrinsically at the star centre
Measuring ranges
M23 177 to 275 ∆VAC M48 DPC71 323 to 550 ∆VAC PPC71 323 to 475 ∆VAC
Ranges
Upper level +2 to +22%
of the nominal voltage
Lower level -22 to -2%
of the nominal voltage
Asymmetry 2 to 22%
of the nominal voltage
Tolerance 2 to 22%
of the nominal voltage
Output Specifications
Output 2 x SPDT relays N.E. Rated insulation voltage 250 VAC
Contact ratings (AgSnO2) µ
Resistive loads AC 1 5 A @ 250 VAC DC 12 5 A @ 24 VDC
Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC
Mechanical life ≥ 30 x 106 operations
Electrical life ≥ 105 operations
(at 5 A, 250 V, cos ϕ = 1)
Operating frequency ≤ 7200 operations/h
Dielectric strength
Dielectric voltage ≥ 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs)
Note: The input voltage must not exceed the maximum rated voltage or drop below the minimum rated voltage
reported above.
Hysteresis
Set points from 2 to 5% 1% Set points from 5 to 22% 2%
Specifications are subject to change without notice (12.05.10) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3- - CARLO English311 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3- - CARLO
pdf1-Selected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3- - CARLEnglish12 Mbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3- - CARLO
pdf2-mostradoSelected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3- - CARLO English630 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 2 relays SETPOINTS 2, adjustable MONITORED VARIABLE 3- - CARLO