Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIABLE 1-phase AC/DC voltage monitoring Others SIZE 45 mm POWER SUPPLY RANGE 115/230 VAC MONITORING FUNCTION Over and under voltage MOUTING DIN-rail INPUT RANGE 500 V DELAY 2, adjustable

More details


Energy Meters Control Analizers

Controls

Monitoring Relays and Measurement Current Transformers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$165.35
2+$161.08
3+$158.97
4+$157.62
5+$156.90
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Monitoring Relays
1-Phase True RMS AC/DC Over and Under Voltage
Types DUC01, PUC01
DUC01 PUC01
• TRMS AC/DC over+under, over+over or under+under voltage monitoring relays
• Selection of measuring range by DIP-switches
• Measuring ranges from 2 to 500 V AC/DC
• Adjustable voltage on relative scale
• Adjustable hysteresis on relative scale
• Adjustable delay function (0.1 to 30 s)
• Programmable latching or inhibit at set level
• Output: 1 or 2 x 8 A SPDT relay N.D. or N.E. selectable
• For mounting on DIN-rail in accordance with
DIN/EN 50 022 (DUC01) or plug-in module (PUC01)
• 45 mm Euronorm housing (DUC01)
or 36 mm plug-in module (PUC01)
• LED indication for relay, alarm and power supply ON
• Galvanically separated power supply
Product Description Ordering Key
DUC 01 D B23 500V
DUC01 and PUC01 are pre- cise TRMS AC/DC over+under, over+over or under+under voltage (selectable by DIP-switch) monitoring relays. The volt- age levels are adjustable separately and have their own time delay.
Type Selection
Owing to the built-in latch function, the ON-position of the relay output can be maintained. Inhibit function can be used to avoid relay operation when not desired (maintenance, transitions). The LED's indicate the state of the alarm and the output relay.
Housing Function Type
Item number
Output
Power supply
Range
Mounting Output Supply: 24 to 48 VAC/DC Supply: 115/230 VAC
DIN-rail 2xSPDT DUC 01 D D48 500V DUC 01 D B23 500V
Plug-in SPDT PUC 01 C D48 500V PUC 01 C B23 500V
Input Specifications
Input (voltage level)
DUC01 Terminals Y1, Y2
PUC01 Terminals 5, 7
Measuring ranges
Direct Internal resist. Max. volt.
Selectable by DIP-switch
2 to 20 V AC/DC > 500 kΩ 350 V
5 to 50 V AC/DC > 500 kΩ 350 V
20 to 200 V AC/DC > 500 kΩ 600 V
50 to 500 V AC/DC > 500 kΩ 600 V
Max. voltage for 1 s 1000 V
Note:
The input voltage cannot raise over 300 VAC/DC with respect to ground (PUC01 only)
Contact input
DUC01 Terminals Z1, Y1
PUC01 Terminals 8, 9
Disabled > 10 kΩ Enabled < 500 Ω Latch disable > 500 ms
Output Specifications
Output 2 x SPDT relays (DUC01)
1 x SPDT relays (PUC01) Rated insulation voltage 250 VAC
Contact ratings (AgSnO2) µ
Resistive loads AC 1 8 A @ 250 VAC DC 12 5 A @ 24 VDC
Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC
Mechanical life ≥ 30 x 106 operations
Electrical life ≥ 105 operations
(at 8 A, 250 V, cos ϕ = 1)
Operating frequency ≤ 7200 operations/h
Dielectric strength
Dielectric voltage ≥ 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs)
Specifications are subject to change without notice (10.06.10) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIAB - CARLO GAVAZZEnglish328 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIAB - CARLO GAVAZZ
pdf1-Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIAB - CARLO GAVAEnglish12 Mbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIAB - CARLO GAVAZZ
pdf2-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIAB - CARLO GAVAZZEnglish630 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 2, adjustable MONITORED VARIAB - CARLO GAVAZZ

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or