PPA01CM44 CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PPA01CM44 CARLO GAVAZZI Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph..

PPA01CM44

PPA01CM44

CARLO GAVAZZI

Available

Ship on today

Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-phase AC voltage monitoring Others SIZE 36 mm POWER SUPPLY RANGE 208÷415 VAC MONITORING FUNCTION Phase sequence, phase loss MOUTING Plug-in INPUT RANGE 208÷415 VAC OTHERS Regenerated voltage detection

More details


Energy Meters Control Analizers

Controls

Monitoring Relays and Measurement Current Transformers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$83.01
3+$79.16
5+$77.75
7+$76.94
10+$76.21
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Monitoring Relays
3-Phase Sequence and Phase Loss
Types DPA01, PPA01
• 3-phase monitoring relays for phase sequence and phase loss
• Detect when all 3 phases are present and have the correct sequence
• Measure their own power supply
• Power supply range: 208 to 690 VAC (+10 -15%)
• Output: 8 A SPDT relay or 8 A DPDT normally energized
• For mounting on DIN-rail in accordance with DIN/EN
50 022 (DPA01) or plug-in module (PPA01)
• 22.5 mm Euronorm housing (DPA01) or 36 mm plug-in module (PPA01)
• LED indication for relay and power supply ON
DPA01 PPA01
Product Description Ordering Key
DPA 01 C M44
3-phase relay for detection of incorrect phase sequence, total and partial phase loss. Supply range from 208 to 690
VAC covered by two multi- voltage relays.
Type Selection
For mounting on DIN-rail or plug-in module. The device detects regenerated voltages up to 85% of the nominal voltage (phase-phase).
Housing Function Type
Item number
Output
Power supply
Mounting Output 208 to 480 VAC 208 to 240 VAC 380 to 480 VAC 380 to 600 VAC 600 to 690 VAC
DIN-rail SPDT DPA 01 C M44 DPA 01 C M60 DPA 01 C M69
DIN-rail DPDT DPA 01 D M23 DPA 01 D M48
Mounting Output 208 to 415 VAC 208 to 240 VAC 380 to 415 VAC
Plug-in SPDT PPA 01 C M44
Plug-in DPDT PPA 01 D M23 PPA 01 D M48
Input Specifications
Output Specifications
Input
L1, L2, L3 DPA01: Terminals L1, L2, L3
PPA01: Terminals 5, 6, 7
Measure their own supply
Measuring ranges
208 to 480 VAC (DPA01CM44) 177 to 550 VAC
380 to 600 VAC (DPA01CM60) 323 to 690 VAC
600 to 690 VAC (DPA01CM69) 510 to 760 VAC
208 to 415 VAC (PPA01CM44) 177 to 475 VAC
208 to 240 VAC (DPA01DM23) 177 to 275 VAC
380 to 480 VAC (DPA01DM48) 323 to 550 VAC
208 to 240 VAC (PPA01DM23) 177 to 275 VAC
380 to 415 VAC (PPA01DM48) 323 to 475 VAC
ON-level > 85% of the mains phase- phase voltage
Output SPDT or DPDT relay, N.E.
Rated insulation voltage 250 VAC
Contact ratings (AgSnO2) µ DPA01C, PPA01C (SPDT):
Resistive loads AC 1 8 A @ 250 VAC DC 12 5 A @ 24 VDC
Small inductive loads AC 15 2.5 A @ 250 VAC DC 13 2.5 A @ 24 VDC
DPA01D, PPA01D (DPDT):
Resistive loads AC 1 8 A @ 250 VAC Small inductive loads AC 15 3 A @ 250 VAC
DC 13 2 A @ 24 VDC
Mechanical life ≥ 30 x 106 operations
Electrical life ≥ 105 operations
(at 8 A, 250 V, cos ϕ = 1)
Operating frequency ≤ 7200 operations/h
Dielectric strength
Dielectric voltage ≥ 2 kVAC (rms) Rated impulse withstand volt. 4 kV (1.2/50 µs)
Specifications are subject to change without notice (24.03.10) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph - CARLO GAVAEnglish110 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph - CARLO GAVA
pdf1-Selected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph - CARLO GAVA
pdf2-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph - CARLO GAVAEnglish630 Kbytespdf1-mostradoSelected parameters OUTPUT SIGNAL 1 relay SETPOINTS 1, fixed MONITORED VARIABLE 3-ph - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or