Selected parameters MOUNTING Flush HOUSING M8 SENSING RANGE up to 2 mm OUTPUT Namur CONNECTION Cable WIRE 2-wire MATERIAL Metal SYSTEM Proximity Sensor Others HOUSING M8 x 51 mm MATERIAL Stainless steel SENSING RANGE 1 mm

More details


Inductive Sensors Proximity Switches

Sensors

Inductive Sensors and Loop Detector

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$34.26
7+$31.12
13+$30.45
19+$30.09
25+$29.87
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Proximity Sensors Inductive
Stainless Steel Housing
Types EI, Ø 6.5, M8, NAMUR
• Stainless steel housing, cylindrical
• Diameter: Ø 6.5, M8
• Short versions
• Sensing distance: 1 to 2 mm
• Output: NAMUR (DIN 19234)
• Protection: Reverse polarity
• 2 m cable
Product Description Ordering Key
EI 0601 NAC S
Proximity switch in Ø 6.5 and M8 housings. Made in accordance with NAMUR DIN 19 234. Short version in
standard stainless steel housing. Amplifier relay SD
... is available.
Type
Housing diameter (mm) Rated operating dist. (mm) Output type
Housing material
Type Selection
Housing Rated operating distance Ordering no. diameter (Sn) NAMUR
Ø 6.5 mm 1 mm 1) EI 0601 NACS
M8 1 mm 1) EI 0801 NACS 1) For flush mounting in metal
M8 2 mm 2) EI 0802 NACS 2) For non-flush mounting in metal
Specifications
Rated operational volt. (Ue) 8.2 VDC (UB) 7 to 9 VDC
(6 to 35 VDC, all specifica-
tions not observed in extended supply range)
Self-inductance Max. 500 µH Self-capacitance Max. 120 nF Current consumption (Io) Activated: ≤1 mA
Not activated: ≥ 2.2 mA
Max.: 9.35 mA
Protection Reverse polarity
Transient voltage ≤ 1 kV/0.5 J (prepared)
Ambient temperature
Operating -25° to +70°C (-13° to +158°F) Storage -30° to +80°C (-22° to +176°F)
Degree of protection IP 67
(Nema 1, 3, 4, 6, 13)
Housing material
Body Stainless steel (1.4301) Front Thermoplastic polyester Back Black PVC
Cable 2 m, 2 x 0.14 mm2
grey PVC, oil proof
Weight (cable included)
Frequency of operating cycles (f)
EI 06 30 g
EI 08 50 g
EI 0601 2000 Hz EI 0801 2000 Hz EI 0802 1500 Hz
Assured operating dist. (Sa) 0 ≤ Sa ≤ 0.81 x Sn
Repeat accuracy (R) ≤ 5%
Hysteresis (H)
(Differential travel) Dependent on amplifier relay
Effective operating dist. (Sr) 0.9 x Sn ≤ Sr ≤ 1.1 x Sn
Usable operating dist. (Su) 0.9 x Sr ≤ Su ≤ 1.1 x Sr
Tightening torque EI 08 3.0 Nm (x)
7.0 Nm (y)
Refer to "Terms Used" Technical information.
Approvals UL, CSA
CE-marking Yes
Specifications are subject to change without notice (20.12.13) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters MOUNTING Flush HOUSING M8 SENSING RANGE up to 2 mm OUTPUT Namur CON - CARLO GEnglish132 Kbytespdf1-mostradoSelected parameters MOUNTING Flush HOUSING M8 SENSING RANGE up to 2 mm OUTPUT Namur CON - CARLO G
pdf1-Selected parameters MOUNTING Flush HOUSING M8 SENSING RANGE up to 2 mm OUTPUT Namur CON - CARLOEnglish12 Mbytespdf1-mostradoSelected parameters MOUNTING Flush HOUSING M8 SENSING RANGE up to 2 mm OUTPUT Namur CON - CARLO G

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or