Selected parameters MONITORED VARIABLE Surge protection Others SIZE 54 mm MONITORING FUNCTION Protection for AC systems MOUTING DIN-rail INPUT RANGE 440÷480 VAC

More details


Inductive Sensors Proximity Switches

Sensors

Inductive Sensors and Loop Detector

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$97.29
3+$92.96
5+$91.39
7+$90.48
9+$90.08
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Monitoring Relays
Surge Arresters for AC systems
Type DSB53 P
• Category IEC / EN / VDE: Class II/Type 2/C
• Connection to TN-C networks
• MOV protection
• Thermal disconnection
• Modular design housing
• Replaceable cartridges
• DIN rail Mounting
• IEC 61643-1 compliant
Product Description Ordering Key
DSB5 3 X P 275
DSB53 series of over- voltage surge protection devices is suitable for the protection of three phase AC mains con- nected devices from the effects of indirect light- ning discharges and induced voltages and is intended to provide pro- tection in zones 1 - 2
tor (MOV) block with thermal disconnection device. This configura- tion of SPD is particular- ly indicated for TN-C Three Phase distribution networks.
Plug in modules facili- tate replacement of failed modules on site without the need of
Type Poles Contact
Three Phase (3+0) MCOV
Type Selection
per IEC 62305. The
replacing and rewiring
modules consists of an high performance Varis-
the whole block.
Contact
None X
1 (relay) C
Max. Continuous Oper. Voltage
MCOV 275Vac/350Vdc 275
385Vac/500Vdc 385
440Vac/580Vdc 440
Cartridges
Ordering Codes
for MCOV 275 arresters DS0275 for MCOV 385 arresters DS0385 for MCOV 440 arresters DS0440
Electrical characteristics
Max. Continuous Oper. Voltage Uc
MCOV 275Vac / 350Vdc
385Vac / 500Vdc
440Vac / 580Vdc
Nominal discharge current In
(8/20)
20kA per pole (40kA)
Max discharge current Imax
(8/20) 40kA per pole (80kA)
Protection level Up
275 <1.5kV
385 <1.9kV
440 <2.2kV
Follow current If NO Response time tA <25ms Thermal protection YES Back-up fuse (if mains >125A) 125A gL
Short-circuit withstand current 25kA/50Hz
Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. REV0 100713 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters MONITORED VARIABLE Surge protection Others SIZE 54 mm MONITORIN - CARLO GAVAZEnglish355 Kbytespdf1-mostradoSelected parameters MONITORED VARIABLE Surge protection Others SIZE 54 mm MONITORIN - CARLO GAVAZ
pdf1-Selected parameters MONITORED VARIABLE Surge protection Others SIZE 54 mm MONITORIN - CARLO GAVEnglish12 Mbytespdf1-mostradoSelected parameters MONITORED VARIABLE Surge protection Others SIZE 54 mm MONITORIN - CARLO GAVAZ

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or