DSB52CA275N CARLO GAVAZZI Selected parameters MONITORED VARIABLE Surge protection Others SIZE 36 mm POWER SU.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

DSB52CA275N CARLO GAVAZZI Selected parameters MONITORED VARIABLE Surge protection Others SIZE 36 mm POWER SU..

DSB52CA275N

DSB52CA275N

CARLO GAVAZZI

Available

Ship on today

Selected parameters MONITORED VARIABLE Surge protection Others SIZE 36 mm POWER SUPPLY RANGE Type 2 MONITORING FUNCTION Protection for AC systems MOUTING DIN-rail INPUT RANGE 280 VAC

More details


Inductive Sensors Proximity Switches

Sensors

Inductive Sensors and Loop Detector

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

Special discounts for registered customers. * This article is obsolete. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Monitoring Relays
Surge Arresters forAC systems
Type DSB52 A
• Category IEC / EN / VDE: Class II/Type 2/C
• Connection to TN-S and TT networks
• MOV or MOV & GDT protection
• Modular design housing
• Replaceable cartridges
• DIN rail Mounting
• IEC 61643-1 compliant
Product Description
Ordering Key
Type Poles Contact Single Phase MCOV
GDT
Type Selection
DSB52 X A 275 N
DSB52series of overvolt- age surge protection devices is suitable for the protection of AC mains connected devices from the effects of indirect lightning discharges and induced voltages and is intended toprovide pro- tection in zones1 - 2 per IEC 62305. The modules consist ineitheranhigh performance Varistor
(MOV) block withthermal disconnectiondevice or an encapsulated air gap device(GDT) whichis usedas a galvanic sepa- rationbetween N andPE conductors. Plugin mod- ulesfacilitatereplace- ment of failed modules onsitewithout theneed ofreplacing andrewiring the wholeblock.
Contact
None X
1 (relay)C
Max. Continuous Oper. Voltage
MCOV 275Vac/350Vdc275
385Vac/500Vdc385
GDT
No (2+0) - (nil)
Yes (1+1)N
Cartridges
Ordering Codes
MOV
for MCOV 275 arrestersDS0275
for MCOV 385 arrestersDS0385
GDT
GDT cartridgeDS0255N (only for DSB52xxxxxN types)
Electrical characteristicswithoutGDT (2+0)DSB52xAxxx versions
Max. Continuous Oper. Voltage Uc
MCOV275Vac / 350Vdc
385Vac / 500Vdc
Nominal discharge current In
(8/20)
20kA per pole (40kA)
Max discharge currentImax
(8/20) 40kA per pole (80kA)
Protection levelUp
275<1.5kV
385<1.9kV
Follow current If NO Response time tA<25ms Thermal protectionYES Back-up fuse (if mains >125A) 125A gL
Short-circuit withstand current 25kA/50Hz
Electrical characteristicswith GDT (1+1) only DSB52xAxxxN versions
Max. Continuous Oper. Voltage Uc
MCOV275Vac / 350Vdc
385Vac / 500Vdc
Nom. discharge currentIn
(8/20)
L-N20kA
N-PE20kA
Max discharge currentImax
(8/20)
L-N40kA
N-PE40kA
Protection levelUp
275 L-N <1.5kV
385 L-N <1.9kV
N-PE<2.0kV
Follow currentIf
N-PE>100ARMS
Response time tA
L-N25ms
N-PE100ms
Thermal protectionYES
Back-up fuse
L-N125A gL
Short-circuit withstand current
L-N25kA/50Hz
Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. REV0 100713 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters MONITORED VARIABLE Surge protection Others SIZE 36 mm POWER SUPP - CARLO GAVAEnglish314 Kbytespdf1-mostradoSelected parameters MONITORED VARIABLE Surge protection Others SIZE 36 mm POWER SUPP - CARLO GAVA
pdf1-Selected parameters MONITORED VARIABLE Surge protection Others SIZE 36 mm POWER SUPP - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters MONITORED VARIABLE Surge protection Others SIZE 36 mm POWER SUPP - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review