CPTDINAV63HA1AX CARLO GAVAZZI Selected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 90 to .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CPTDINAV63HA1AX CARLO GAVAZZI Selected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 90 to ..

CPTDINAV63HA1AX

CPTDINAV63HA1AX

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 90 to 260V AC/DC OUTPUT DIGITAL INPUT Analogue output 20mA INPUT TYPE 3-phase AC CONNECTION CT/VT COMMUNICATION None Others RANGE 120/(208)VLL 5(6)AAC DISPLAY None VARIABLES V, A, Hz, W,VA, var, PF, kWh, kvarh, Hours DIGITAL INPUTS none PULSE none ALARMS none ANALOGUE 1

More details


Energy Meters Control Analizers

Controls

Energy Management, Software and Accessories

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$321.15
2+$314.22
3+$312.69
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Energy Management
Compact Power Transducer
Type CPT-DIN “Advanced version”
• One digital output and RS485 communication port (2 wires only)
• 16 freely configurable alarms with OR/AND logic linkable
to up to 2 digital outputs
• RS422/485/RS232 communication port (MODBUS- RTU), iFIX SCADA compatibility
Product Description
• Class 1 (kWh), Class 2 (kvarh)
• Accuracy ±0.5 F.S. (current/voltage)
• Compact power transducer
• Instantaneous variables data format: 4 DGT
• Energies data format: 8+1 DGT
• System variables and phase measurements: VLL, VLN, A, Amax, An, Admd, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, WL1, WL2, WL3 max, var, PF, PFL1, PFL2, PFL3 min, Hz, ASY
• Four quadrant power measurement
• Energy measurements: total and partial kWh and kvarh
(according to EN62053-21 and EN62053-23)
• Hour counter (5+2 DGT)
• TRMS meas. of distorted sine waves (voltages/currents)
• Universal power supply: 90 to 260 VAC/DC, 18 to 60 VAC/DC
• Dimensions: 45x83.5x98.5mm
• Voltage asymmetry, phase sequence, phase loss control
• Up to 3 analogue outputs (20mA or 10VDC)
• 2 digital outputs
How to order CPT-DIN AV5 3 H A3 AX
3-phase compact power transducer. Particularly rec- ommended for the measure- ment of the main electrical variables also on board of machines.
Housing for DIN-rail mount-
ing, with up to 3 analogue outputs, or RS485 communi- cation port or alarm outputs or “Dupline” bus. Parameters programmable by means of CptASoft.
Model Range code System
Power supply Outputs Option
How to order
CptASoft-kit
Type Selection
CptASoft: software to program the working parameters of the transducer and to read the energies and the instanta- neous variables. The kit includes the communication cable.
Range codes
AV5: 400/690VL-L/1/5(6)AAC VL-N: 185 V to 460 V
VL-L: 320 V to 800 V
AV6: 120/208VL-L/1/5(6)AAC VL-N: 45 V to 145 V
VL-L: 78 V to 250 V Phase current: 0.01A to 6A
Neutral current: 0.05A to 6A
Input specifications
System
3 : 1-2-3-phase, balanced/ unbalanced load, with or without neutral
1 : 1-3-phase, balanced load (*)
(*) Note: the 3-phase balanced load measurement requires the connection of the neutral accord- ing to fig. 15 and 16 in the final part of this document.
Outputs
R2: 2-relay outputs
O2: 2-open collector outputs
A1: 1-analogue output:
0/4 to 20mA DC
A3: 3-analogue outputs:
0/4 to 20mA DC
V1: 1-analogue output:
0 to 10V DC
V3: 3-analogue outputs:
0 to 10V DC
S1: RS485/RS422 port
S2: RS232 port
DB: Dupline bus
Options
AX: advanced functions
Power supply L: 18 to 60 VAC/VDC
H: 90 to 260 VAC/VDC
Rated inputs System type: 3
Current 3 (internal current transformers) Voltage 4
System type: 1
Current 1 (internal CT) Voltage 2
Accuracy (RS485) Imax: 6A, Vmax: 400VLN (690VLL), (@25°C ±5°C, R.H. ≤60%) In: 5A, Vn: 230VLN (400VLL)
CT: 1, VT (PT): 1
Range accuracy: 0.02In to 0.05In
Current ±(0.5%FS) or ±(1%RDG+2DGT)
Neutral current ±(2%RDG+3DGT) Phase-phase voltage ±(0.5%RDG+2DGT) Phase-neutral voltage ±(0.5%RDG+2DGT)
Active and Apparent power, ±(1.5%RDG+3DGT) Reactive power ±(3%RDG+3DGT)
Range accuracy: 0.05In to Imax
Current ±(0.5%RDG+2DGT) Neutral current ±(1%RDG+3DGT) Phase-phase voltage ±(0.5%RDG+2DGT)
Phase-neutral voltage ±(0.5%RDG+2DGT) Active and Apparent power, ±(1%RDG+3DGT)
Specifications are subject to change without notice CPT-DIN A DS ENG 011012 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 90 to 260V - CARLO GAVAZZEnglish656 Kbytespdf1-mostradoSelected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 90 to 260V - CARLO GAVAZZ
pdf1-Selected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 90 to 260V - CARLO GAVAEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Transducers MOUNTING DIN Rail POWER SUPPLY 90 to 260V - CARLO GAVAZZ

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or