NSO02DB24SC CARLO GAVAZZI Selected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Othe..

NSO02DB24SC

NSO02DB24SC

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Others SIZE 22 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail OTHERS 2 NO inputs

More details


Safety

Controls

Safety Modules

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$131.20
2+$127.60
4+$124.67
5+$123.85
7+$123.19
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Safety Modules
Safety Gate and Safety Magnetic Sensor
Types NSO02D, NSO13D
Screw, fixed
Screw, detachable
• Safety Category 4, Performance Level e, according to EN 13849-1
• Safety Category 4 according to EN 954-1
• Category 0 Emergency Stop (EN 60204-1)
• Input type: 2 NO
• 2 x 6 A NO safety outputs (NSO02D)
• 3 x 6 A NO safety outputs and 1 x 6 A NC auxiliary output (NSO13D)
• Automatic / manual or monitored manual reset
• Single / double channel operations
• LED indication for outputs status and power supply ON
• Connection by fixed or detachable terminals
• For mounting on DIN-rail in accordance with DIN/EN 50
022
• 22.5 mm Euronorm housing
Product Description
Ordering Key N SO 0 2 D B24 S A
Safety gate and safety magnetic sensor modules according to EN 60204-1, EN
292-1/-2, EN 418 and
EN1088.
This family of safety module in Safety Category 4,
Type Selection
Performance Level e, includes fixed screw and detachable screw as well as automatic/manual or monitored manual restart versions.
Housing Function Auxiliary outputs Safety outputs Safety category Power supply Terminals Start/Reset type
Auxiliary outputs
Safety
outputs Terminals Start/Reset type Supply: 24 VAC/DC
2 NO Screw, fixed Automatic / Manual N SO 0 2 D B24 S A
2 NO Screw, fixed Monitored manual N SO 0 2 D B24 S C
2 NO Screw, detachable Automatic / Manual N SO 0 2 D B24 D A
2 NO Screw, detachable Monitored manual N SO 0 2 D B24 D C
1 NC 3 NO Screw, fixed Automatic / Manual N SO 1 3 D B24 S A
1 NC 3 NO Screw, fixed Monitored manual N SO 1 3 D B24 S C
1 NC 3 NO Screw, detachable Automatic / Manual N SO 1 3 D B24 D A
1 NC 3 NO Screw, detachable Monitored manual N SO 1 3 D B24 D C
Time Specification
Output Specification
Delay ON energisation < 150 ms Delay ON de-energisation < 30 ms Recovery time ≥ 30 ms Channel simultaneity
during outputs closing Infinite
Input operating to START
operating delay
NSO...C > 500 ms
Input Specifications
Function 2 NO, voltage free
Input current
Terminals S11-S12 max 10 mA Terminals S21-S22 max 10 mA
External contact resistance
Terminals S11-S12 max. 60Ω
Terminals S21-S22 max. 60Ω
Safety outputs Category 4, Performance
Level e (EN 13849-1) NSO02D 2 NO (13-14, 23-24) NSO13D 3 NO (13-14, 23-24, 33-34)
Auxilary output
NSO13D 1 NC (41-42)
Rated insulation voltage 250 VAC (rms)
Contact ratings (AgSnO2) 2 µm Au
Safety outputs
Resistive loads AC1 6 A @ 230 VAC DC12 6 A @ 24 VDC
Small inductive loadsAC15 3 A @ 230 VAC DC13 2.5 A @ 24 VDC
Auxiliary output 6A, 24 VAC/DC
External contact fuse
protection 5 A fast, 4 A slow
Mechanical life > 107 operations Electrical life > 105 operations Dielectric strength
Dielectric voltage 4 kVAC (rms)
1 Specifications are subject to change without notice. Pictures are just an example. For special features and/or customization, please ask to our sales network. 27/09/12

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Others - CARLO GAVAEnglish463 Kbytespdf1-mostradoSelected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Others - CARLO GAVA
pdf1-Selected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Others - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Others - CARLO GAVA
pdf2-mostradoSelected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Others - CARLO GAVAEnglish392 Kbytespdf1-mostradoSelected parameters FUNCTION Safety gate SAFETY CATEGORY 4 SAFETY OUTPUT 2 NO Others - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or