WM1496AV63HDG CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

WM1496AV63HDG CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 2..

WM1496AV63HDG

WM1496AV63HDG

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 260V AC/DC OUTPUT DIGITAL INPUT None INPUT TYPE 3-phase AC CONNECTION CT/VT COMMUNICATION Profibus Others RANGE 78V to 250VLL 1/5(6)AAC DISPLAY 3x3 DGT VARIABLES kWh, kvarh, W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz, Amax, Admd max, Wdmd max DIGITAL INPUTS none PULSE none ALARMS Virtual ANALOGUE none

More details


Energy Meters Control Analizers

Controls

Energy Management, Software and Accessories

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$574.62
2+$570.43
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Energy Management
Power Analyzer
Type WM14-96 “Profibus DP”
• Protection degree (front): IP65
• Front dimensions: 96x96mm
• Class 1 (active energy)
• Class 2 (reactive energy)
• Accuracy ±0.5 F.S. (current/voltage)
• Power analyzer
• Display of instantaneous variables: 3x3 digit
• Display of energies: 8+1 digit
• System variables and phase measurements: W, Wdmd, var, VA, VAdmd, PF, V, A, An, Admd, Hz
• Amax, Admd max, Wdmd max indication
• Energy measurements: kWh and kvarh
• Hour counter (5+2 DGT)
• TRMS meas. of distorted sine waves (voltages/currents)
• Galvanically insulated measuring inputs
• Profibus DP-V0 serial port
• Alarms (visual only) VLN, An
• Power supply: 90 to 260VAC/DC
Product Description
How to order WM14-96 AV5 3 H DGX
3-phase power analyzer with built-in programming key- pad. Particularly recom- mended for displaying the main electrical variables.
Housing for panel mounting, (front) protection degree IP65 and Profibus DP communica- tion port.
Model Range code System
Power supply
Option
Type Selection
Range codes
AV5: 380/660VL-L/5(6)AAC VL-N: 185 V to 460 V VL-L: 320 V to 800 V
AV6: 120/208VL-L/5(6)AAC VL-N: 45 V to 145 V
VL-L: 78 V to 250 V Phase current: 0.03A to 6A Neutral current: 0.09 to 6A
System
3 : 1-2-3-phase, balanced/unbalanced load,with or without neutral
Power supply
H: 90 to 260VAC/DC
Options
DG: Profibus DP + galvanic insulated measuring inputs
Input specifications
Rated inputs
Current 3
Voltage 4
Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%) 1150W-VA-var, FS:230VLN,
400VLL AV6: 285W-VA-var, FS:57VLN, 100VLL
Current 0.25 to 6A: ±(0.5% FS +1DGT)
0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current 0.25 to 6A: ±(1.5% FS +1DGT)
0.09Ato0.25A:±(0.5%FS+7DGT) Phase-phase voltage ±(1.5% FS +1 DGT)
Phase-neutral voltage ±(0.5% FS + 1 DGT)
Active and Apparent power 0.25 to 6A: ±(1% FS +1DGT)
0.03A to 0.25A: ±(1% FS
+5DGT)
Reactive power 0.25 to 6A: ±(2% FS +1DGT)
0.03Ato0.25A:±(2%FS +5DGT) Active energy Class 1 (start up “I”: 30mA) Reactive energy Class 2 (start up “I”: 30mA)
Frequency ±0.1Hz (48 to 62Hz)
Additional errors
Humidity ≤0.3% FS, 60% to 90% RH
Temperature drift ≤ 200ppm/°C
Sampling rate 1400 samples/s @ 50Hz
1700 samples/s @ 60Hz
Display refresh time 700ms
Display
Type LED, 14mm
Read-out for instant. var. 3x3 DGT
Read-out for energies 3+3+3 DGT (Max indication:
999 999 99.9)
Read-out for hour counter 1+3+3 DGT (Max. indication:
9 999 9.99)
Measurements Current, voltage, power, power factor, frequency, energy, TRMS measurement of distorted waves.
Coupling type Direct
Specifications are subject to change without notice WM14-96PDS 080906 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 260V - CARLO GAVAEnglish364 Kbytespdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 260V - CARLO GAVA
pdf1-Selected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 260V - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING Panel POWER SUPPLY 90 to 260V - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or