WM14DINAV63HO2S1AX M14DINAV63HO2S1AX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

WM14DINAV63HO2S1AX M14DINAV63HO2S1AX CARLO GAVAZZI Selected parameters FUNCTION Power Analyzers MOUNTING DIN..

WM14DINAV63HO2S1AX

M14DINAV63HO2S1AX

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Power Analyzers MOUNTING DIN Rail POWER SUPPLY 9 to 32 VDC OUTPUT DIGITAL INPUT DC output (Open Collector) INPUT TYPE 3-phase AC CONNECTION CT/VT COMMUNICATION RS485 Others RANGE 78V to 250VLL 1/5(6)AAC DISPLAY 3x3 DGT VARIABLES VLL,VLN,VLN min max,VA,VAdmd dmdmax,W,Wmax dmd,Wdmdmax,var,Hz,ASY,A,An,Amin max dmdmax,PF,PFmin,FFT DIGITAL INPUTS none PULSE 2 ALARMS 2 ANALOGUE none

More details


Inductive Sensors Proximity Switches

Sensors

Inductive Sensors and Loop Detector

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$321.76
2+$314.84
3+$313.40
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Energy Management
Power Analyzer
Type WM14 DIN “Advanced version”
• Protection degree (front): IP40
• 2 digital outputs
• 16 freely configurable alarms with OR/AND logic linkable with up to 2 digital outputs
• RS422/485 serial output (MODBUS-RTU), iFIX SCADA
compatibility
Product Description
• Class 1 (kWh), Class 2 (kvarh)
• Accuracy ±0.5 F.S. (current/voltage)
• Power Analyzer
• Instantaneous variables read-out: 3 DGT
• Energies readout: 8+1 DGT
• System variables: VLL, VLN, An, Admd max, VA, VAdmd, VAdmd max, W, Wdmd, Wdmd max, var, PF, Hz, ASY
• Single phase variables: VLL, VLN, VLN min, VLN max, A, Amin, Amax, Admd, VA, W, Wdmd, Wmax, var, PF, PFmin
• Harmonic analysis (FFT) up to the 15th harmonic (cur-
rent and voltage)
• Four quadrant power measurement
• Energy measurements: total and partial kWh and kvarh
• Hour counter (5+2 DGT)
• TRMS meas. of distorted sine waves (voltages/currents)
• Universal power supply: 90 to 260 VAC/DC, 18 to 60 VAC/DC
• Front dimensions: 107,8x90mm (6 DIN modules)
• Voltage asymmetry, phase sequence, phase loss control
How to order WM14-DIN AV5 3 H R2 S1 AX
3-phase advanced power analyzer with integrated pro- gramming key-pad. Particu- larly recommended for the measurement of the main electrical variables.
Housing for DIN-RAIL mount- ing, with RS485 communica- tion port or pulse and/or alarm outputs.
Model Range code System
Power supply
Output 1
Output 2
Option
Type Selection
Range codes
AV5: 380/660VL-L/1/5(6)AAC VL-N: 185 V to 460 V
VL-L: 320 V to 800 V
AV6: 120/208VL-L/1/5(6)AAC VL-N: 45 V to 145 V
VL-L: 78 V to 250 V
System
3 : 1, 2 or 3 phase, balanced/unbalanced load, with or without neutral
Power supply
Output 1
R2: 2-relay outputs
O2: 2-open collector outputs
Output 2
XX: None
S1: RS485/RS422 port
Options
Phase current: 0.03A to 6A
Neutral current: 0.09A to 6A
L: 18 to 60 VAC/VDC
H: 90 to 260 VAC/VDC
AX: advanced functions
Input specifications
Rated inputs System type: 3 - phase
Current 3 (by Shunts) Voltage 4
Accuracy (display, RS485) with CT=1 and VT=1 AV5: (@25°C ±5°C, R.H. ≤60%) 1150W-VA-var, FS:230VLN,
400VLL AV6: 285W-VA-var, FS:57VLN, 100VLL
Current 0.25 to 6A: ±(0.5% FS +1DGT)
0.03Ato0.25A:±(0.5%FS+7DGT) Neutral current 0.25 to 6A: ±(1.5% FS +1DGT)
0.09Ato0.25A:±(1.5%FS+7DGT)
Phase-phase voltage ±(1.5% FS +1 DGT)
Phase-neutral voltage ±(0.5% FS + 1 DGT)
Active and Apparent power, 0.25 to 6A: ±(1% FS +1DGT)
0.03A to 0.25A: ±(1% FS
+5DGT)
Reactive power 0.25 to 6A: ±(2% FS +1DGT)
0.03A to 0.25A: ±(2% FS
+5DGT)
Active energy Class 1 (start up current: 30mA) Reactive energy Class 2 (start up current: 30mA) Frequency ±0.1Hz (48 to 62Hz) Harmonic distortion ±3% F.S. (up to 15th harmonic)
(F.S.: 100%)
Specifications are subject to change without notice WM14 DIN A DS ENG 230508 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING D - CARLO GAVAZZI - WM14DINAV63HO2S1AX - M1English1024 Kbytespdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING D - CARLO GAVAZZI - WM14DINAV63HO2S1AX - M1
pdf1-Selected parameters FUNCTION Power Analyzers MOUNTING D - CARLO GAVAZZI - WM14DINAV63HO2S1AX - English12 Mbytespdf1-mostradoSelected parameters FUNCTION Power Analyzers MOUNTING D - CARLO GAVAZZI - WM14DINAV63HO2S1AX - M1

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields