EBSSM2310M CARLO GAVAZZI Selected parameters FUNCTION Interval OUTPUT SIGNAL Solid state Others INPUT RANGE .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EBSSM2310M CARLO GAVAZZI Selected parameters FUNCTION Interval OUTPUT SIGNAL Solid state Others INPUT RANGE ..

EBSSM2310M

EBSSM2310M

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Interval OUTPUT SIGNAL Solid state Others INPUT RANGE 60 s - 600 s MOUNTING DIN-rail (22,5 mm)/panel SIZE 22,5 mm POWER SUPPLY RANGE 24÷230 VAC SOCKET N/A

More details


Timers

Controls

Timers

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$26.78
9+$23.92
17+$23.38
25+$23.11
33+$22.93
*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Timers Interval Type EBS
• Fail-safe two-wire connection
• Low-cost
• Multi-voltage: 24-230 VAC
• Interval timer
• Time range: 0,5 s - 10 m
• Knob-adjustable time setting
• Output: SCR 10-500 mA (screws) and SCR 10-700mA (Fast-ON)
• For mounting on DIN-rail in accordance with
DIN/EN 50 022
• 22,5 mm small Euronorm housing
SCREW FASTON
Product Description
Ordering Key
EBS S M23 10S F
Small, lowcostmonofunc- tion timer with adjustable time setting. 2-wire connec- tionforeasyandfail-safe use (see diagram). For mountingon DIN-rail or
Type Selection
directly on surface by screw. The timer is used e.g. with industrialrelays or3-phase contactors.
Housing Function Small E-line Output
Power supply
Time range
Fast-ON connection
Mounting OutputTime rangeConnection Supply: 24 - 230 VAC
For DIN-rail SCR 0.5 - 10 sScrews EBS S M23 10S
or for screw SCR 0.1 -1 mScrews EBS S M23 1M
SCR 1 - 10 mScrews EBS S M23 10M
For DIN-rail SCR 0.5 - 10 sFast-ONEBS S M23 10S F
or for screw SCR 0.1 -1 mFast-ONEBS S M23 1M F
SCR 1 - 10 mFast-ONEBS S M23 10M F
TimeSpecifications
Time ranges
10 s0.5 - 10 s
1 m0.1 - 1 m
10 m1- 10 m
Time range accuracyMax. setting: actual time
≥ max. set time
min. setting: actual time
≤ min. set time
Repeat accuracy ≤ 0.2%
Time variation
Within rated power supply ≤ 0.1%/V
and ambient temperature ≤ 0.2%/°C
Reset
Time and output Power supply interruption
≥ 200 ms
Output Specifications
OutputSCR
Output current
Maximum load current
(screw terminals)500 mA (Fast-ON connection) 700 m
Maximum current for 100 ms
(screw terminals)5.5 A (Fast-ON connection) 7 A
Minimum load current10 m
Leakage current≤ 3.5 mA @ 230 V
typ.: 2 m
Voltage drop≤ 8 VAC
typ.: 5 VAC @ 50 mA
Supply Specifications
Power supplyOvervoltage cat. III (IEC 60664) Rated operational voltage(IEC 60038)
24-230 VAC, -10/+15% Rated insulation voltage None
Specifications are subject to change without notice (20.07.06)1

Datasheet - PDF

Title:Language:Size:Type: