Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Others SIZE 22 mm CONNECTIONS Screw-fixed POWER SUPPLY 230VAC MOUNTING DIN-rail AUX OUTPUT 1 NC

More details


Safety

Controls

Safety Modules

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$153.22
2+$149.18
3+$147.18
4+$145.90
6+$144.87
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Emergency Stop and Safety Gate Modules
NA13D
• Safety Category 4, Performance Level e according to EN13849-1
• Safety Category 4 according to EN954-1
• Category 0 Emergency Stop
• 3 NO safety outputs
• 1 NC auxiliary output
• 24 VAC / VDC, 110 VAC or 230 VAC power supply
• Single/dual channel
• Automatic or manual reset
• Self monitoring
• Failure diagnosis by LEDs
• Approvals: TÜV NORD, CULUS
Product Description
Ordering Key
NA13 D 230
Emergency Stop and Safety Gate modules according to EN 60204-1, EN 292-1/-2, EN 418 and EN 1088.
This family of safety module in Safety Category 4, Perfor-
Type Selection
Power supply
24 VAC/VDC
110 VAC
230 VAC
mance Level e, includes 24
VAC/VDC, 110 VAC or 230
VAC.
Every model is characterized by dual channel input and safety output contacts with force guided relay outputs.
References
NA13D NA13D110CG NA13D230CG
Housing Application Controlled Devices Safety Outputs Safety Category Power Supply
Electrical Specifications
Power supply
NA13D 24 VAC/DC ± 10% NA13D110CG 110 VAC ± 10% NA13D230CG 230 VAC ±10%
Power consumption 4 VA / 4 W Safety outputs 3 NO Auxiliary outputs 1 NC Contact ratings
Resistive loads AC1 6 A @ 230 VAC
DC12 6 A @ 24 VDC Small inductive loads AC15 3 A @ 230 VAC
DC13 2.5 A @ 24 VDC
Contact fuse protection 5 A fast or 4 A slow
Insulation voltage Pollution degree: 2
Overvoltage Category:
3 / 250 V
24 VAC/DC xxx AC Supply to input none 4 kV 1.2/50µs Supply to output 4 kV 1.2/50µs 4 kV 1.2/50µs Input to output 4 kV 1.2/50µs 4 kV 1.2/50µs
Time Specifications Environmental Specifications
Delay on energisation < 150 ms Delay on de-energisation < 30 ms Channel simultaneity ∞
Operating temperature -25°C ... + 55°C
Storage temperature -25°C ... + 65°C
Mechanical Specifications
Protection degree terminals IP 20
Protection degree housing IP 40
Housing material Polyamid PA6.6
Housing type 22.5 mm housing models
Mounting DIN rail
Max cross section 2.5 mm2 rigid wire
of external conductors 2.5 mm2 flexible wire
Dimensions 22.5 x 99 x 114 mm
Weight
NA13D 170 g
NA13D230CG, NA13D110CG 238 g
Specifications are subjected to change without notice (13.01.10) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Others - CARLO GEnglish118 Kbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Others - CARLO G
pdf1-Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Others - CARLOEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 4 SAFETY OUTPUT 3 NO Others - CARLO G

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or