NA13CT CARLO GAVAZZI Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NA13CT CARLO GAVAZZI Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others..

NA13CT

NA13CT

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others SIZE 22 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VDC MOUNTING DIN-rail AUX OUTPUT 1 NC OTHERS Also 18 VAC power supply

More details


Safety

Controls

Safety Modules

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$183.72
2+$179.10
3+$176.82
4+$175.35
5+$175.06
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Emergency Stop and Safety Gate Modules
NA13CT
• Safety Category 3 according to EN 954-1
• Category 1 Emergency Stop
• 3 NO delayed safety outputs
• 1 NC auxiliary delayed output
• 24 VDC or 18 VAC power supply
• Single channel operation
• Automatic or manual reset
• Failure diagnosis by LEDs
Product Description
Ordering Key
NA13 C T
Emergency Stop and Safety Gate modules for category 1 emergency STOP according to
EN 60204-1, EN 292-1 /-2, EN
418, EN 1088 and EN 954-1.
Housing Application Controlled Devices Safety Outputs Safety Category Delayed Outputs
Electrical Specifications
Power supply 18 VAC ± 10% 50-60Hz /
24 VDC ± 10%
Power consumption 2 VA / 2 W Safety outputs 3 NO delayed Auxiliary outputs 1 NC delayed Contact ratings
Resistive loads AC1 6 A @ 230 VAC
Small inductive loads AC15 3 A @ 230 VAC
DC13 3 A @ 24 VDC (50000 cycles)
Safety output
contact fuse protection 4 A fast or 4 A delayed
Insulation voltage
Supply to input none
Supply to output 4 kV 1.2/50µs
Input to output 4 kV 1.2/50µs
Pollution degree 2
Overvoltage category III
Time Specifications Environmental Specifications
Delay on energisation ≤ 100 ms
Delay on de-energisation 1.2 s ± 0.5 sec @ 24 VDC
Recovery time Td + 0,4 s Delay time Td 1 s Channel simultaneity Infinite
Operating temperature -25°C ... + 65°C
Storage temperature -25°C ... + 65°C
Mechanical Specifications
Protection degree terminals IP 20
Protection degree housing IP 40
Max cross section
of external conductors 2.5 mm2 flexible wire
2
Housing material Polyamid PA 6.6
2.5 mm
rigid wire
Housing type 22.5 mm housing models
Mounting DIN rail
Dimensions 22.5 x 99 x 114 mm
Weight 200 g
Specifications are subjected to change without notice (20.04.07) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others SIZ - CAREnglish133 Kbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others SIZ - CAR
pdf1-Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others SIZ - CEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others SIZ - CAR
pdf2-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others SIZ - CAREnglish392 Kbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 3 SAFETY OUTPUT 3 NO Others SIZ - CAR

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or