NDS12BB24DA CARLO GAVAZZI Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO O.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NDS12BB24DA CARLO GAVAZZI Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO O..

NDS12BB24DA

NDS12BB24DA

CARLO GAVAZZI

Available

Ship on today

Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO Others SIZE 22 mm CONNECTIONS Screw-detachable POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail AUX OUTPUT 1 NO OTHERS Automatic/Manual start

More details


Safety

Controls

Safety Modules

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$203.12
2+$198.15
3+$195.68
4+$194.30
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Safety Modules
Emergency Stop and Safety Gate
Type NDS12B
Screw, fixed Screw, detachable
• Safety Category 2 according to
EN 13849-1: 2007
• Category 0 Emergency Stop (EN 60204-1) for 1 instan- taneous safety output
• Category 1 Emergency Stop (EN 60204-1) for 1 delayed safety output
• Adjustable safety output delay (from 0.1 to 10 s)
• 2 x 5 A NO safety outputs (1 instantaneous + 1 delayed)
• 1 x 5 A NO auxiliary output (instantaneous)
• Automatic or manual reset
• Two single channel inputs (E-Stop, Guard)
• Feedback circuit for external contactors monitoring
• LED indications for outputs and inputs (E-Stop, Guard)
status, power supply ON and feedback circuit fault
• Connection by fixed or detachable terminals
• For mounting on DIN-rail in accordance with DIN/EN
50 022
• 22.5 mm Euronorm housing
Product Description Ordering Key N DS 1 2 B B24 S A
Emergency Stop and Safety Gate modules according to EN 60204-1 and EN 13849-1:
2007.
This family of safety mod- ules in Safety Category 2 is suitable for applications where both istantaneous
Type Selection
and delayed outputs are needed.
Available with both fixed screw and detachable screw terminals.
Housing Function Auxiliary outputs Safety outputs Safety category Power supply Terminals Start/Reset type
Auxiliary Safety Terminals Start/Reset type Supply: 24 VAC/DC
outputs outputs
1 NO 2 NO Screw, fixed Automatic / Manual N DS 1 2 B B24 S A
1 NO 2 NO Screw, detachable Automatic / Manual N DS 1 2 B B24 D A
Time Specifications
Delay ON energisation ≤ 40 ms
Delay ON de-energisation
Terminals
23-24, 33-34 ≤ 40 ms
17-18 0.1 ÷ 10 s
Recovery time < 300 ms
Channel simultaneity during
inputs closing Infinite
Input Specifications
Function 2 NO, voltage free
Input current
Terminals
S11-S12, S33-S34 max 6 mA S21-S22 max 8 mA Y1-Y2 max 8 mA
Output Specifications
Safety outputs Category 2
(EN 13849-1: 2007)
1 NO (17-18), delayed
1 NO (23-24), instantaneous
Auxilary output 1 NO (33-34), instantaneous
Contact ratings (AgSnO2) 0.2 µm Au
Safety outputs (17-18, 23-24)
Resistive loads AC1 5 A @ 230 VAC DC12 5 A @ 24 VDC
Small inductive loads AC15 1.5 A @ 230 VAC DC13 1.2 A @ 24 VDC
Auxiliary output (33-34)
Resistive loads AC1 5 A @ 230 VAC DC12 5 A @ 24 VDC
Small inductive loads AC15 1.5 A @ 230 VAC DC13 1.2 A @ 24 VDC
External contact fuse
protection 4 A fast or 4 A delayed
Mechanical life > 107 operations
Electrical life > 105 operations
Specifications are subject to change without notice (03.10.07) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO Oth - CARLO GAVAEnglish221 Kbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO Oth - CARLO GAVA
pdf1-Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO Oth - CARLO GAEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO Oth - CARLO GAVA
pdf2-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO Oth - CARLO GAVAEnglish392 Kbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 2 SAFETY OUTPUT 2 NO Oth - CARLO GAVA

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or