Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Others SIZE 26 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail

More details


Safety

Controls

Safety Modules

* Brand new produt in its original packing covered by the warranties and certifications provided by CARLO GAVAZZI

QuantityPrice
1+$78.10
3+$74.42
6+$72.65
8+$72.02
11+$71.50
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Emergency Stop and Safety Gate Modules
M22A21A
• Safety Category 1 according to EN 954-1
• Category 0 Emergency Stop
• 1 NO safety output
• 24 VAC / VDC power supply
• Single/dual channel inputs
• Automatic reset
• Failure diagnosis by LEDs
Product Description
Ordering Key
M22 A 2 1 A
Emergency Stop and Safety Gate module according to EN 60204-1, EN 292-1/-2,
EN 418, EN 1088 and EN 954-1. Housing Application Controlled Devices Safety Outputs Safety Category
Electrical Specifications
Power supply 24 VAC ± 10% 50-60Hz /
24 VDC ± 10%
Power consumption 2 VA / 2 W
Input current/voltage 50 mA @ 24 VDC
Safety outputs 1 NO
Auxiliary outputs –
Safety output switching
voltage /current /capability 250Vac/6A/1660VA
Safety output
contact fuse protection 6 A fast or 4 A delayed
Insulation voltage 2.5 KV for signal parts
4.0 KV for safety output parts: Pollution degree 2
Overvoltage category III
Time Specifications Environmental Specifications
Delay on energisation ≤ 25 ms Delay on de-energisation ≤ 25 ms Recovery time ≥ 25 ms Channel simultaneity ∞
Operating temperature -0°C ... + 55°C
Storage temperature -25°C ... + 65°C
Mechanical Specifications
Protection degree terminals IP 20
Protection degree housing IP 30
Max cross section
of external conductors 1.5 mm2 flexible wire
2
Housing material Nylon flammability class
2.5 mm
rigid wire
V0-UL94
Housing type 26 mm housing models
Mounting DIN rail
Dimensions 26 x 82 x 101 mm
Weight 120 g
Specifications are subjected to change without notice (27.04.07) 1

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Others - CARLO English76 Kbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Others - CARLO
pdf1-Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Others - CARLEnglish12 Mbytespdf1-mostradoSelected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Others - CARLO

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or