M22A21A CARLO GAVAZZI Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Other.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

M22A21A CARLO GAVAZZI Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Other..

M22A21A

CARLO GAVAZZI

Selected parameters FUNCTION Emergency stop SAFETY CATEGORY 1 SAFETY OUTPUT 1 NO Others SIZE 26 mm CONNECTIONS Screw-fixed POWER SUPPLY 24 VAC/DC MOUNTING DIN-rail

More details


Home > CARLO GAVAZZI

* Brand new product in its original packaging covered by the warranties and certifications provided by CARLO GAVAZZI

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Emergency Stop and Safety Gate Modules
M22A21A
• Safety Category 1 according to EN 954-1
• Category 0 Emergency Stop
• 1 NO safety output
• 24 VAC / VDC power supply
• Single/dual channel inputs
• Automatic reset
• Failure diagnosis by LEDs
Product Description
Ordering Key
M22 A 2 1 A
Emergency Stop and Safety Gate module according to EN 60204-1,EN292-1/-2,
EN 418, EN 1088 and EN 954-1. Housing Application Controlled Devices Safety Outputs Safety Category
Electrical Specifications
Power supply 24 VAC ± 10% 50-60Hz /
24 VDC ± 10%
Power consumption2 VA / 2 W
Input current/voltage 50 mA @ 24 VDC
Safety outputs1 NO
Auxiliary outputs–
Safety output switching
voltage /current /capability 250Vac/6A/1660VA
Safety output
contact fuse protection 6 A fast or 4 A delayed
Insulation voltage2.5 KV for signal parts
4.0 KV for safety output parts: Pollution degree 2
Overvoltage category III
TimeSpecificationsEnvironmental Specifications
Delay on energisation ≤ 25 ms Delay on de-energisation≤ 25 ms Recovery time≥ 25 ms Channel simultaneity ∞
Operating temperature-0°C ... + 55°C
Storage temperature -25°C ... + 65°C
Mechanical Specifications
Protection degree terminals IP 20
Protection degree housing IP 30
Max cross section
of external conductors1.5 mm2 flexible wire
2
Housing materialNylon flammability class
2.5 mm
rigid wire
V0-UL94
Housing type26 mm housing models
MountingDIN rail
Dimensions26 x 82 x 101 mm
Weight 120 g
Specifications are subjected to change without notice (27.04.07) 1

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.