EK210-40-21 SK825441-DD ABB EK210-40-21 48V DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

EK210-40-21 SK825441-DD ABB EK210-40-21 48V DC Contactor

EK210-40-21

SK825441-DD

ABB

Available

Ship on today

EK210-40-21 48V DC Contactor

More details


Contactor Relays

Contactors and overload relays

Large contactors EH

* Brand new produt in its original packing covered by the warranties and certifications provided by ABB

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



A 4-pole Contactor suitable for Distribution and Rail way applications AC and DC switching. Operated with control voltage, versions from 24….690 AC, 50/60 Hz and 24-220 V DC

Ordering

  • EAN:
    7320500094990
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    200 mm
  • Product Net Depth:
    200 mm
  • Product Net Height:
    175 mm
  • Product Net Weight:
    6.6 kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    240 mm
  • Package Level 1 Length:
    240 mm
  • Package Level 1 Height:
    190 mm
  • Package Level 1 Gross Weight:
    7.05 kg

Technical

  • Number of Main Contacts NO:
    4
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    2
  • Number of Auxiliary Contacts NC:
    2
  • Rated Operational Voltage:
    Main Circuit 1000 V
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 310 A
    (690 V) 40 °C 350 A
    (690 V) 70 °C 250 A
  • Rated Operational Current AC-3 (Ie):
    (1000 V) 55 °C 113 A
    (690 V) 55 °C 210 A
    (220 / 230 / 240 V) 55 °C 210 A
    (440 V) 55 °C 210 A
    (440 V) 55 °C Q55C415V:210 A
    (380 / 400 V) 55 °C 210 A
    (500 V) 55 °C 210 A
  • Rated Operational Power AC-3 (Pe):
    (500 V) 132 kW
    (1000 V) 160 kW
    (690 V) 160 kW
    (220 / 230 / 240 V) 59 kW
    (380 / 400 V) 110 kW
    (440 V) 110 kW
    (415 V) 110 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 355 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 360 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1680 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2300 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 800 A
  • Maximum Electrical Switching Frequency:
    AC-3 300 cycles per hour
    AC-1 300 cycles per hour
    AC-2 / AC-4 120 cycles per hour
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    8 kV
  • Mechanical Durability:
    10 million
  • Maximum Mechanical Switching Frequency:
    3600 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    DC Operation 48 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1200 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 65 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 52 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 20…40 ms
    Between Coil De-energization and NO Contact Opening 7.5…15 ms
    Between Coil De-energization and NC Contact Closing 10…18 ms
    Between Coil Energization and NC Contact Opening 15…35 ms
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
  • Connecting terminals (delivered in open position) Main poles:
    Flat type c/w screws and bolts
  • Terminal Type:
    Screw Terminals

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+55 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -50…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m
  • RoHS Status:
    Following EU Directive 2002/95/EC August 18, 2005 and amendment

Technical UL/CSA

  • General Use Rating UL/CSA:
    (600 V AC) 300 A

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching

Datasheet - PDF

Title:Language:Size:Type:
pdf-EK210-40-21 48V DC Contactor - ABB - EK210-40-21 - SK825441-DDEnglish91 Kbytespdf-EK210-40-21 48V DC Contactor - ABB - EK210-40-21 - SK825441-DD

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or