AF2650-30-11 1SFL667001R7011 ABB AF2650-30-11 100-250V 50/60Hz / 100-250 DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AF2650-30-11 1SFL667001R7011 ABB AF2650-30-11 100-250V 50/60Hz / 100-250 DC Contactor

1SFL667001R7011

ABB

AF2650-30-11 100-250V 50/60Hz / 100-250 DC Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays > Contactors "A" SECRLP

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total price: $10,448.05
Unit price: $10,448.05

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



A 3-phase Contactor suitable for various applications such as Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 100-250 V, AC/DC

Ordering

  • EAN:
    7320500481431
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    438.0mm
  • Product Net Depth:
    244.0mm
  • Product Net Height:
    422.0mm
  • Product Net Weight:
    41.000kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Width:
    250 mm
  • Package Level 1 Length:
    440 mm
  • Package Level 1 Height:
    430 mm
  • Package Level 1 Gross Weight:
    43 kg
  • Package Level 1 EAN:
    7320500481431

Technical

  • Number of Main Contacts NO:
    3
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 1000 V
  • Rated Frequency (f):
    Main Circuit 50/60 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 2650 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 55 °C 2350 A
    (690 V) 40 °C 2650 A
    (1000 V) 40 °C 2650 A
    (1000 V) 55 °C 2350 A
    (690 V) 70 °C 2120 A
    (1000 V) 70 °C 2120 A
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 10000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 2200 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 12000 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 5500 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 8400 A
  • Maximum Electrical Switching Frequency:
    AC-1 15 cycles per hour
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 1000 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Mechanical Durability:
    0.3 million
  • Maximum Mechanical Switching Frequency:
    300 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    60 Hz 100…250 V
    50 Hz 100…250 V
    DC Operation 100…250 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A
    Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A
    Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 50…80 ms
    Between Coil De-energization and NO Contact Opening 35…55 ms
    Between Coil De-energization and NC Contact Closing 35…55 ms
    Between Coil Energization and NC Contact Opening 50…80 ms
  • Connecting Capacity-Main Circuit:
    Bar 100 mm
  • Connecting Capacity-Auxiliary Circuit:
    Solid 2x1…4 mm²
    Flexible with Insulated Ferrule 2x0.75…2.5 mm²
    Stranded 2x1…4 mm²
    Flexible 2x0.75…2.5 mm²
    Flexible with Ferrule 2x0.75…2.5 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type:
    Main Circuit: Bars

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -40…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V
  • General Use Rating UL/CSA:
    (600 V AC) 2700 A

Certificates and Declarations (Document Number)

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching
  • UNSPSC:
    39121529

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.