AF116-40-11-14 1SFL427101R1411 ABB AF116-40-11-14 Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

AF116-40-11-14 1SFL427101R1411 ABB AF116-40-11-14 Contactor

1SFL427101R1411

ABB

AF116-40-11-14 Contactor

More details


Low-voltage industrial components > Power contactor, AC switching

Contactors and overload relays > AF contactors 100A to 370A

* Brand new product in its original packaging covered by the warranties and certifications provided by ABB

Total price: $435.55
Unit price: $435.55

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 690 V. Operated with wide control voltage range 250-500 V, 50/60 Hz and DC

Ordering

  • EAN:
    7320500503928
  • Minimum Order Quantity:
    1 piece
  • Customs Tariff Number:
    85364900

Dimensions

  • Product Net Width:
    120mm
  • Product Net Depth:
    128,1mm
  • Product Net Height:
    150mm
  • Product Net Weight:
    2.07kg

Container Information

  • Package Level 1 Units:
    1 piece
  • Package Level 1 Gross Weight:
    2.27 kg

Technical

  • Number of Main Contacts NO:
    4
  • Number of Main Contacts NC:
    0
  • Number of Auxiliary Contacts NO:
    1
  • Number of Auxiliary Contacts NC:
    1
  • Rated Operational Voltage:
    Main Circuit 690 V
  • Rated Frequency (f):
    Main Circuit 50 Hz
  • Conventional Free-air Thermal Current (Ith):
    acc. to IEC 60947-4-1, Open Contactors q = 40 °C 160 A
  • Rated Operational Current AC-1 (Ie):
    (690 V) 40 °C 160 A
    (690 V) 70 °C 130 A
    (690 V) 60 °C 145 A
  • Rated Operational Current AC-3 (Ie):
    (220 / 230 / 240 V) 55 °C 116 A
    (415 V) 55 °C 116 A
    (440 V) 55 °C 116 A
    (380 / 400 V) 55 °C 116 A
  • Rated Operational Power AC-3 (Pe):
    (220 / 230 / 240 V) 30 kW
    (380 / 400 V) 55 kW
    (440 V) 75 kW
    (415 V) 55 kW
  • Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
    8 x Ie AC-3
  • Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
    10 x Ie AC-3
  • Short-Circuit Protective Devices:
    gG Type Fuses 200 A
  • Rated Short-time Withstand Current (Icw):
    at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1300 A
    at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A
  • Maximum Breaking Capacity:
    cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A
  • Maximum Electrical Switching Frequency:
    AC-1 300 cycles per hour
  • Rated Insulation Voltage (Ui):
    acc. to UL/CSA 600 V
    acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
  • Rated Impulse Withstand Voltage (Uimp):
    Main Circuit 8 kV
  • Mechanical Durability:
    5 million
  • Maximum Mechanical Switching Frequency:
    300 cycles per hour
  • Coil Operating Limits:
    (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
  • Rated Control Circuit Voltage (Uc):
    60 Hz 250…500 V
    50 Hz 250...500 V
    DC Operation 250…500 V
  • Coil Consumption:
    Pull-in at Max. Rated Control Circuit Voltage 60 Hz 205 V·A
    Holding at Max. Rated Control Circuit Voltage DC 4 W
    Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A
    Pull-in at Max. Rated Control Circuit Voltage DC 204 W
    Pull-in at Max. Rated Control Circuit Voltage 50 Hz 205 V·A
    Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A
  • Operate Time:
    Between Coil Energization and NO Contact Closing 20…55 ms
    Between Coil De-energization and NO Contact Opening 40…70 ms
  • Connecting Capacity-Main Circuit:
    Rigid Cu-Cable 1x10…95 mm²
    Flexible 2x10…70 mm²
  • Connecting Capacity-Auxiliary Circuit:
    Solid 2x1…4 mm²
    Flexible with Insulated Ferrule 2x0.75…2.5 mm²
    Stranded 2x1…4 mm²
    Flexible 2x0.75…2.5 mm²
    Flexible with Ferrule 2x0.75…2.5 mm²
  • Degree of Protection:
    acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
    acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
  • Terminal Type:
    Double Clamp

Environmental

  • Ambient Air Temperature:
    Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
    Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
    Close to Contactor for Storage -40…+70 °C
  • Maximum Operating Altitude Permissible:
    3000 m

Technical UL/CSA

  • Maximum Operating Voltage UL/CSA:
    Main Circuit 600 V

Classifications

  • ETIM 5:
    EC000066 - Magnet contactor, AC-switching

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.